Bug #1949

Monitoring system is overloaded when monitoring time is longer than interval

Added by Ruben S. Montero about 8 years ago. Updated about 8 years ago.

Status:ClosedStart date:04/23/2013
Priority:NormalDue date:
Assignee:Carlos Martín% Done:

0%

Category:Core & System
Target version:Release 4.0
Resolution: Pull request:
Affected Versions:OpenNebula 4.0

Description

If a host is in init state multiple monitoring requests can be issued if each monitor action last longer than a monitoring interval. This may lead to overload the system (unbounded monitor process, ....)

Associated revisions

Revision 930ef686
Added by Ruben S. Montero about 8 years ago

bug #1949: Add MONITORING States. Change DISABLED behavior

Revision 61fc5c57
Added by Ruben S. Montero about 8 years ago

bug #1949: Add OCA state

Revision 0c35a80a
Added by Ruben S. Montero about 8 years ago

bug #1949: remove function definition

Revision e267375c
Added by Carlos Martín about 8 years ago

Bug #1949: Add new states to oca, sunstone, ozones

Revision 28d8e44e
Added by Carlos Martín about 8 years ago

Bug #1949: Prevent bug #1800 from reappearing

Revision de3df143
Added by Ruben S. Montero about 8 years ago

bug #1949: Update last_monitor

History

#1 Updated by Ruben S. Montero about 8 years ago

  • Status changed from Assigned to Closed

Also available in: Atom PDF