Bug #1949
Monitoring system is overloaded when monitoring time is longer than interval
Status: | Closed | Start date: | 04/23/2013 | |
---|---|---|---|---|
Priority: | Normal | Due date: | ||
Assignee: | Carlos Martín | % Done: | 0% | |
Category: | Core & System | |||
Target version: | Release 4.0 | |||
Resolution: | Pull request: | |||
Affected Versions: | OpenNebula 4.0 |
Description
If a host is in init state multiple monitoring requests can be issued if each monitor action last longer than a monitoring interval. This may lead to overload the system (unbounded monitor process, ....)
Associated revisions
bug #1949: Add MONITORING States. Change DISABLED behavior
bug #1949: Add OCA state
bug #1949: remove function definition
Bug #1949: Add new states to oca, sunstone, ozones
bug #1949: Update last_monitor
History
#1 Updated by Ruben S. Montero about 8 years ago
- Status changed from Assigned to Closed